Precautions and Responsibilities
Precautions specified in IEC 60825-1 and FDA CFR Title 21 Part 1040 are as follows:
Requirement |
Class 2 |
Class 2M |
Class 3R |
Class 3B |
Remote interlock |
Not required |
Not required |
Not required |
Required* |
Key control |
Not required |
Not required |
Not required |
Required – cannot remove key when in use* |
Power-on delays |
Not required |
Not required |
Not required |
Required* |
Beam attenuator |
Not required |
Not required |
Not required |
Required* |
Emission indicator |
Not required |
Not required |
Not required |
Required* |
Warning signs |
Not required |
Not required |
Not required |
Required* |
Beam path |
Not required |
Not required |
Terminate beam at useful length |
Terminate beam at useful length |
Specular reflection |
Not required |
Not required |
Prevent unintentional reflections |
Prevent unintentional reflections |
Eye protection |
Not required |
Not required |
Not required |
Required under special conditions |
Laser safety officer |
Not required |
Not required |
Not required |
Required |
Training |
Not required |
Not required |
Required for operator and maintenance personnel |
Required for operator and maintenance personnel |
*LMI Class 3B laser components do not incorporate these laser safety items. These items must be added and completed by customers in their system design. For more information, see Class 3B Responsibilities.