Gocator 3500 Series

The Gocator 3500 series consists of the following models:

MODEL

3504

3506

3520

Scan Rate (Hz)

6

6

3

Imagers (megapixels)

5

5

5

Clearance Distance (CD) (mm)

52.5

87.0

203

Measurement Range (MR) (mm)

7

25.0

150

Field of View (mm)

12.1 x 13.2 (near)

12.7 x 16.4 (maxY)

13.0 x 15.0 (far)

27.0 x 45.0 (near)

30.0 x 45.0 (far)

179 x 115 (near)

282 x 175 (far)

Repeatability Z (µm)

0.2

2.0

4.6

Resolution XY (µm)

6.7 - 7.1

20 - 25

74 - 121

VDE Accuracy (mm)

n/a

0.012 mm(1)

0.090 mm(2) - 0.200 mm(3)

Accuracy XYZ (µm)4

6

n/a

n/a

Input Voltage (Power)

+24 to +48 VDC (25 Watts); Ripple +/- 10%

48 VDC (50 Watts); Ripple +/- 10%

Operating Temp.

0 to 50° C

0 to 40° C

Storage Temp.

-30 to 70° C

Dimensions (mm)

49x152x177.5

49 x 136 x 170

55 x 167 x 260

Weight (kg)

1.77

1.52

2.6

  1. Based on 2634, Part 2.
  2. VDE within central 100 mm measurement range.
  3. VDE within full 150 mm measurement range.
  4. Based on sphere-fitting at various positions in the scan volume.

Field of View and Resolution XY are specified as [X] x [Y], near to far.

The following diagram illustrates some of the terms used in the table above.

ALL 3500 SERIES MODELS

 

Light Source Blue LED (465 nm)
Interface Gigabit Ethernet
Inputs Differential Encoder, Trigger
Outputs

2x Digital output, RS-485 Serial (115 kBaud)

Analog Output (4 – 20 mA)

Housing Gasketed aluminum enclosure, IP67
Vibration Resistance 10 to 55 Hz, 1.5 mm double amplitude in X, Y and Z directions, 2 hours per direction
Shock Resistance 15 g, half sine wave, 11 ms, positive and negative for X, Y and Z directions

Mechanical dimensions, CD/FOV/MR, and the envelope for each sensor model are illustrated on the following pages.